Main Title: Untersuchungen über die Interaktionen des Augeninnendrucks mit anderen intraokularen Fundamentalparametern und ihre Rückwirkung auf die messtechnischen Eigenschaften von Tonometern bei der klinischen Evaluierung
Translated Title: Investigations about the interaction of intraocular pressure with other fundamental parameters and their response for the metrological properties of tonometers during clinical evaluation
Author(s): Schwenteck, Thomas
Advisor(s): Kraft, Marc
Referee(s): Kraft, Marc
Draeger, Joerg
Granting Institution: Technische Universität Berlin, Fakultät V - Verkehrs- und Maschinensysteme
Type: Doctoral Thesis
Language: German
Language Code: de
Abstract: Mit einer limitierten Anzahl von Messgeräten wurden signifikante Wechselbeziehungen zwischen dem intraokularen Druck und anderen ophthalmologischen Messgrößen untersucht. Die okuläre Pulsamplitude ist eine wichtige Messgröße, die sich nur mit sehr wenigen Geräten (dynamische Konturtonometer Pascal, Blutflusstonograph OBF-Lab) bestimmen lässt. An beiden Messgeräten konnte ein mittleres Korrelationsniveau zwischen diesen zwei Messgrößen festgestellt werden. Die zentrale Hornhautdicke wurde mit dem Ultraschall- Pachymeter SL-3000 bestimmt. Die Messungen des intraokularen Drucks erfolgten mit dem Applanationstonometer der Bauart AT 870 (Hersteller Haag-Streit). Zwischen diesen beiden Größen konnte keine Korrelation verifiziert werden. Augeninnendruck und Blutflussgrößen, Pulsvolumen und pulsativer okulärer Blutfluss, wurden auf Korrelationen untersucht. Nur schwache Korrelationsgrade waren dabei zu verzeichnen. Zu temporären Messgrößen, wie systolische, diastolische Zeit und Pulsrate, zeigt der intraokulare Druck keine Korrelation. Zusätzlich erfolgten Korrelationsanalysen zwischen verschiedenen Messgrößen, die mit dem okulären Blutflusstonographen bestimmt wurden. Dabei konnten mittlere, gute und sehr gute Korrelationsniveaus konstatiert werden. Ein Mischungszustand von Perfusionsgrößen in Verbindung mit einem solchen zwischen okulärer Pulsamplitude und intraokularem Druck führte zu einem mittleren Korrelationsgrad. Verschiedene messbare geometrische Größen am Menschenauge (z. B. Korneadicke, Hornhautaußenradien, Vorderkammertiefe, Kammerwinkel) lassen sich mit dem Universalmessgerät Pentacam bestimmen, die auf Korrelationen zum Augeninnendruck untersucht wurden. Weder bei der Korneadicke, gemessen im Hornhautscheitelpunkt und am Applanationskreisrand vom Tonometer Ocuton-A, noch bei den Korneaaußenradien konnte eine Korrelation zum Augeninnendruck verifiziert werden. Auch bezüglich Vorderkammervolumen, Kammerwinkel und vordere Kammertiefe in Verbindung zum intraokularen Druck war keine Korrelation festzustellen. Verschiedene dargestellte Modellentwicklungen, wie z. B. virtuelles Kegel-,Rotationsparaboloidmodell,dienten zur theoretischen Erklärung und Deutung der vorhandenen Messresultate.
With a limited number of measuring devices were investigated significant correlation between intraocular pressure and other ophthalmological measuring quantities. The ocular pulse amplitude is an important measuring quantity, only measureable with very few devices (dynamical contour monometer Pascal, blood flow tonograph OBF-Lab). Between both devices a medium level of correlation were established. The central cornea thickness was determined with ultrasound pachymeter SL-3000. The measurements of intraocular pressure followed by means of applanation tonometer of design AT 870 (manufacturer Haag-Streit). Between both quantities a correlation was not proved. Intraocular pressure and blood flow quantities, pulse volume and palatial ocular blood flow, were investigated regarding correlations. Only weak correlation levels were detected. The intraocular pressure shows none correlation to temporary measuring quantities, like systolic, diastolic time, and pulse rate. Additional correlation analyses followed between various measuring quantities, determined by ocular blood flow tomography. Medium, high, and very high levels of correlation were detected. A mix state of perfusion quantities in connection with such between ocular pulse amplitude an intraocular pressure led to a medium level of correlation. Various measureable geometrical quantities on human eye (e. g. cornea thickness, external cornea radii, front chamber depth, and chamber angle) were determined by applying the universal measuring device Pentacam, which were investigated concerning correlations to intraocular pressure. Neither for cornea thickness, measured on cornea apex point and on applanation circle boundary of tonometer Ocuton-A nor for external cornea radii were proved a correlation to intraocular pressure. Also regarding front chamber volume, chamber angle, and front chamber depth in connection to intraocular pressure was none correlation detected. Various presented model developments, for instance virtual shell-,rotation paraboloid model, served for theoretical explanation and interpretation of available measuring results.
URI: urn:nbn:de:kobv:83-opus4-56687
http://depositonce.tu-berlin.de/handle/11303/4484
http://dx.doi.org/10.14279/depositonce-4187
Exam Date: 26-Jun-2014
Issue Date: 3-Dec-2014
Date Available: 3-Dec-2014
DDC Class: 600 Technik, Technologie
610 Medizin und Gesundheit
Subject(s): Intraokularer Druck
Augentonometrie
Blutflusstonographie
geometrische Augengrößen
Korrelation
Intraocular pressure
eye tonometry
blood flow tonography
geometrical eye quantities
correlation
Usage rights: Terms of German Copyright Law
Appears in Collections:Institut für Konstruktion, Mikro- und Medizintechnik » Publications

Files in This Item:
File Description SizeFormat 
schwenteck_thomas.pdf7.2 MBAdobe PDFThumbnail
View/Open


Items in DepositOnce are protected by copyright, with all rights reserved, unless otherwise indicated.