Inst. Energietechnik

163 Items

Recent Submissions
Risk assessment for internal spaces regarding aerosols loaded with virus

Kriegel, Martin ; Hartmann, Anne (2020-06)

Based on known equations a risk assessment for rooms with different sizes has been performed if an infected person has entered the room. Depending on the air change the maximum duration of stay until a critical limit of inhaled virus has been reached has been calculated. In specific situations the load is influenced by the ventilation effectiveness as well as the vitality of the virus.

Risikobewertung von Innenräumen zu virenbeladenen Aerosolen

Kriegel, Martin ; Hartmann, Anne (2020-06)

Aufbauend auf bekannten Gleichungen wird eine Risikobewertung with Räume unterschiedlicher Größe durchgeführt, wenn eine infizierte Person den Raum betritt. In Abhängigkeit vom Luftwechsel wird eine maximale Aufenthaltszeit bestimmt, bevor ein kritische Menge an Viren eingeatmet wird. In konkreten Situationen wird die Last zusätzlich noch von der Lüftungswirksamkeit und der Vitalität der Viren...

Eine Marktübersicht der Blockchain in der Energiewirtschaft

Corusa, Andreas ; Predel, Johannes ; Schöne, Nikolas (2020-08)

Die Studie „Eine Marktübersicht der Blockchain in der Energiewirtschaft“ unterteilt die Blockchain-Technologie in technische Module und ordnet dabei vorhandene Blockchain-Lösungen anhand der entwickelten Methodik ein. Ausgangspunkt der Studie ist eine fundierte Marktanalyse über die derzeitige Nutzung der Blockchain in der Energiewirtschaft. Dabei ist die Studie ein wichtiger Ratgeber für die A...

Aerosol emission is increased in professional singing

Mürbe, Dirk ; Fleischer, Mario ; Lange, Julia ; Rotheudt, Hansjörg ; Kriegel, Martin (2020-09)

In this study, emission rates of aerosols emitted by professional singers were measured with a laser particle counter under cleanroom conditions. The emission rates during singing varied between 753.4 and 6095.37 P/s. Emission rates for singing were compared with data for breathing and speaking. Significantly higher emission rates were found for singing. The growth rates between singing and spe...

Erhöhung der Aerosolbildung beim professionellen Singen

Mürbe, Dirk ; Fleischer, Mario ; Lange, Julia ; Rotheudt, Hansjörg ; Kriegel, Martin (2020-08)

In dieser Studie werden mittels Partikelzähler gemessene Partikelquellstärken von emittierten Aerosolen beim Singen bei professionellen Sängerinnen und Sängern vorgestellt und mit publizierten Daten für das Atmen und Sprechen verglichen. In der untersuchten Kohorte von acht Probandinnen und Probanden liegen die Partikelquellstärken beim Singen zwischen 753.4 und 6093.14 P/s. Die Steigerungsfakt...

Risikobewertung von virenbeladenen Aerosolen anhand der CO2-Konzentration

Hartmann, Anne ; Kriegel, Martin (2020-07)

Basierend auf der Kohlenstoffdioxidkonzentration werden analytische Betrachtungen der Aersolkonzentration im Raum angestellt. Aufbauend auf einer kritischen Dosis-Viren wird zusätzlich untersucht, wie lange sich Personen bei einer gegebenen CO2-Konzentration im Raum aufhalten können.

Risk assessment of aerosols loaded with virus based on CO2-concentration

Hartmann, Anne ; Kriegel, Martin (2020-07)

Based on the carbon dioxid concentration analytical investigations regarding the aerosol concentration in the room has been performed. With a critical dose of virus it has been investigated how long a person may stay in the room, if a given CO2 concentration has occured in the room.

ISHPC 2021 proceedings – online pre-conference 2020

(2020-08)

For decades there has been intense research and development on sorption heat pumping and cooling processes; still, looking at the sales numbers, it is mainly a niche technology. The current transition to an energy system based on renewables changes the boundary conditions. Sorption heat pumps will have an indispensable place in this context, especially for its potential to make use of waste hea...

Steady state meaurements of a 40 kW absorption heat transformer

Corrales Ciganda, José Luis ; Cudok, Falk (2020-08-01)

The repository includes the steady state measurement of a 40 kW absorption heat transformer prototype. The data has been obtained at a laboratory test rig and obtained in the frame of two different research projects for the deveopement of this technology. The measurement equipment description, measurement methodology and resulting systematic uncertainty and standard devition of the obtained val...

Performance of absorption chillers in field tests

Hüls Güido, Walther ; Lanser, Wolfgang ; Petersen, Stefan ; Ziegler, Felix (2018-02-05)

Absorption chillers can use waste heat, solar heat, or excess heat by cogeneration facilities to supply chilled water. Therefore, absorption chillers are important components for poly-generation, which can improve plant utilization and efficiency of the overall energy supply system. Currently, 27 new small and medium-scale (30–160 kW cooling capacity) absorption chillers with high efficiency i...

Airborne infection prevention: a comparisson of mixing ventilation and displacement ventilation in a meeting room

Brockmann, Gerrid ; Kriegel, Martin (2020-07-27)

Usually, displacement ventilation is characterized by a higher ventilation effectiveness than mixing ventilation. Is it therefore a better prevention of airborne infection? This CFD investigation shows a correlation between the ventilation effectiveness and the contribution of the exhaled air of an infectious person to other occupants in a meeting room.

Parameterstudie zur Risikobewertung in Innenräumen durch virenbeladene Aerosole

Hartmann, Anne ; Kriegel, Martin (2020-07)

In Ergänzung zu bisherigen Betrachtungen, in denen mit einer festen kritischen Dosis sowie Anzahl von Viren je Aerosol gerechnet wurde, werden Untersuchungen zum Einfluss dieser Parameter auf die maximale Aufenthaltszeit in Innenräumen angestellt.

Parameter study for risk assessment in internal spaces regarding aerosols loaded with virus

Hartmann, Anne ; Kriegel, Martin (2020-07)

In addtion to previous investigations, in which a defined critical dose as well as a certain number of viruses per aerosol has been used, in this investigation the influence of these parameters on the maximum time of stay in internal spaces has been estimated.

Ausbreitungsdistanz und -dynamik von Aerosolen in Innenräumen durch Konvektionsströme

Kriegel, Martin ; Hartmann, Anne (2020-07)

Aerosole verbreiten sich aufgrund von Konvektion in Innenräumen. In der aktuellen Untersuchung wird der Einfluss der freien (thermischer Auftrieb) und der erzwungenen (mechanische Belüftung) Konvektion gegenüber gestellt. Die durch den thermischen Auftrieb bewegte Luftmenge ist bereits in geringem Abstand über der Wärmequelle höher als die Luftmenge, die von der Lüftungsanlage im selben Abstan...

Spreading distance and dynamic of aerosols in internal spaces by convection flows

Kriegel, Martin ; Hartmann, Anne (2020-07)

Because of convection aerosols will be dispersed in internal spaces. In this investigation the influence of free (thermal buoyancy) and forced (mechanical ventilation) convection has been compared. The air flow, which has been moved by the thermal bouyancy is even after a short distance above the heat source higher than the air flow caused by the mechamical ventilation system.

Risk assessment of rehearsal rooms for choir singing regarding aerosols loaded with virus

Hartmann, Anne ; Mürbe, Dirk ; Kriegel, Martin ; Lange, Julia ; Fleischer, Mario (2020-07)

Based on measurements regarding the particle emission during singing for 3 typical rooms for choirs (1 rehearsal room, 2 concert halls) as well as an office as a reference case the concentration of virus loaden aerosols has been estimated.

Risikobewertung von Probenräumen für Chöre hinsichtlich virenbeladenen Aerosolen

Hartmann, Anne ; Mürbe, Dirk ; Kriegel, Martin ; Lange, Julia ; Fleischer, Mario (2020-07)

Aufbauend auf Messungen zur der Partikelemission während des Singens werden für 3 typische Chorräume (1 Probenraum und 2 Konztersäale) sowie einen Referenzfall Büro Aerosolkonzentrationen für virenbeladene Aerosole bestimmt.

Superstructure-Based Optimization of Vapor Compression-Absorption Cascade Refrigeration Systems

Mussati, Sergio F. ; Morosuk, Tatiana ; Mussati, Miguel C. (2020-04-10)

A system that combines a vapor compression refrigeration system (VCRS) with a vapor absorption refrigeration system (VARS) merges the advantages of both processes, resulting in a more cost-effective system. In such a cascade system, the electrical power for VCRS and the heat energy for VARS can be significantly reduced, resulting in a coefficient of performance (COP) value higher than the value...

Emissionsrate und Partikelgröße von Bioaerosolen beim Atmen, Sprechen und Husten

Hartmann, Anne ; Lange, Julia ; Rotheudt, Hansjörg ; Kriegel, Martin (2020)

Die Quellstärke sowie die Größenverteilung of Aerosolen, die von Probanden während des Atmens, Sprechens und Hustens abgegeben wurden, wurden in einem Prüfstand bestimmt. Die meisten der gemessenen Partikel waren kleiner as 5 Mikrometer.

Emission rate and particle size of bioaerosols during breathing, speaking and coughing

Hartmann, Anne ; Lange, Julia ; Rotheudt, Hansjörg ; Kriegel, Martin (2020)

The emission rate as well as the size distribution of aerosols emitted by probands during breathing, speaking and coughing have been estimated in test stand measurements. Most have the particles, which have been measured have been smaller than 5 micrometer.