Unsteady Effects on NOx Measurements in Pulse Detonation Combustion

dc.contributor.authorHanraths, Niclas
dc.contributor.authorBohon, Myles D.
dc.contributor.authorPaschereit, Christian Oliver
dc.contributor.authorDjordjevic, Neda
dc.date.accessioned2021-12-06T18:24:46Z
dc.date.available2021-12-06T18:24:46Z
dc.date.issued2021-03-04
dc.description.abstractEmission measurements from unsteady combustion systems such as Pulse Detonation Combustion (PDC) are challenging due to the inherently large variations in pressure, temperature, composition, and flow velocity of the exhaust gas. Comparison of experimental data is additionally complicated by differences in operating conditions and gas sampling setup between different facilities. Qualitative considerations with regard to the sampling process from PDC, based on one-dimensional simulations, indicate a systematic influence of the sampling setup and extraction process on the resulting concentration measurements. Therefore, operating frequency, sample time, fill time, as well as PDC outlet and probe geometry were varied experimentally in order to assess the degree to which each of these parameters impact the resulting measured NOx in order to better inform researchers of these effects when making measurements. It was shown that measured NOx emissions can vary significantly depending on the choice of these parameters and therefore care must be exercised in order to reduce the influence of the sampling technique when aiming for comparable results.en
dc.description.sponsorshipDFG, 317741329, Minderung der NOx-Emissionen bei pulsierender Detonationsverbrennungen
dc.description.sponsorshipTU Berlin, Open-Access-Mittel – 2021en
dc.identifier.eissn1573-1987
dc.identifier.issn1386-6184
dc.identifier.urihttps://depositonce.tu-berlin.de/handle/11303/13983
dc.identifier.urihttp://dx.doi.org/10.14279/depositonce-12756
dc.language.isoenen
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en
dc.subject.ddc621 Angewandte Physikde
dc.subject.otherNOxen
dc.subject.otheremission measurementen
dc.subject.otherpulse detonation combustionen
dc.subject.othertransient gas samplingen
dc.titleUnsteady Effects on NOx Measurements in Pulse Detonation Combustionen
dc.typeArticleen
dc.type.versionpublishedVersionen
dcterms.bibliographicCitation.doi10.1007/s10494-021-00252-3en
dcterms.bibliographicCitation.issue3en
dcterms.bibliographicCitation.journaltitleFlow, Turbulence and Combustionen
dcterms.bibliographicCitation.originalpublishernameSpringer Natureen
dcterms.bibliographicCitation.originalpublisherplaceDordrecht [u.a.]en
dcterms.bibliographicCitation.pageend809en
dcterms.bibliographicCitation.pagestart781en
dcterms.bibliographicCitation.volume107en
tub.accessrights.dnbfreeen
tub.affiliationFak. 5 Verkehrs- und Maschinensysteme::Inst. Strömungsmechanik und Technische Akustik (ISTA)::FG Verbrennungskinetikde
tub.affiliation.facultyFak. 5 Verkehrs- und Maschinensystemede
tub.affiliation.groupFG Verbrennungskinetikde
tub.affiliation.instituteInst. Strömungsmechanik und Technische Akustik (ISTA)de
tub.publisher.universityorinstitutionTechnische Universität Berlinen

Files

Original bundle
Now showing 1 - 1 of 1
Loading…
Thumbnail Image
Name:
hanraths_etal_2021.pdf
Size:
2.87 MB
Format:
Adobe Portable Document Format
Description:

Collections