Loading…
Thumbnail Image

Absolute calibration of a single-photon avalanche detector using a bright triggered single-photon source based on an InGaAs quantum dot

Georgieva, Hristina; López, Marco; Hofer, Helmuth; Kanold, Niklas; Kaganskiy, Arsenty; Rodt, Sven; Reitzenstein, Stephan; Kück, Stefan

We apply an InGaAs quantum dot based single-photon source for the absolute detection efficiency calibration of a silicon single-photon avalanche diode operating in Geiger mode. The single-photon source delivers up to (2.55 ± 0.02) × 106 photons per second inside a multimode fiber at the wavelength of 929.8 nm for above-band pulsed excitation with a repetition rate of 80 MHz. The purity of the single-photon emission, expressed by the value of the 2nd order correlation function g(2)(τ = 0), is between 0.14 and 0.24 depending on the excitation power applied to the quantum dot. The single-photon flux is sufficient to be measured with an analog low-noise reference detector, which is traceable to the national standard for optical radiant flux. The measured detection efficiency using the single-photon source remains constant within the measurement uncertainty for different photon fluxes. The corresponding weighted mean thus amounts to 0.3263 with a standard uncertainty of 0.0022.
Published in: Biomedical Optics Express, 10.1364/OE.430680, Optical Society of America