Reduzierung von MR-Bildartefakten durch gezielte Kombination para-und diamagnetischer Materialien

dc.contributor.authorAnders, E.
dc.date.accessioned2018-10-02T14:02:54Z
dc.date.available2018-10-02T14:02:54Z
dc.date.issued2002
dc.descriptionDieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.de
dc.descriptionThis publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.en
dc.description.abstractA theoretical mathematical model of dual component paramagnetic and diamagnetic material to cancel metal-induced magnetic resonance imaging (MRI)artifacts was investigated and evaluated. The magnetization produced by material causes gradient linearity distortion. By using materials with opposing paramagnetic and diamagnetic properties it is supposed to compensate these effects. Therefore the interferences by paramagnetic and diamagnetic materials on Images in a closed 1.5 Tesla high field magnetic resonance imaging System were experimentally examined for different types of sequences and correlated to their magnetic susceptibility. Basing on this results the concept of dual-component materials to solve the problems of MRI-artifacts was theoretically checked by using the finite element method and experimentally in the MRI.en
dc.identifier.eissn1862-278X
dc.identifier.issn0013-5585
dc.identifier.urihttps://depositonce.tu-berlin.de/handle/11303/8276
dc.identifier.urihttp://dx.doi.org/10.14279/depositonce-7427
dc.language.isode
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subject.ddc610 Medizin und Gesundheitde
dc.subject.otherMRIen
dc.subject.otherartifactsen
dc.subject.othercompensationen
dc.subject.othersusceptibilityen
dc.subject.otherdual-component materialsen
dc.titleReduzierung von MR-Bildartefakten durch gezielte Kombination para-und diamagnetischer Materialiende
dc.typeArticleen
dc.type.versionpublishedVersionen
dcterms.bibliographicCitation.doi10.1515/bmte.2002.47.s1b.750
dcterms.bibliographicCitation.issues1b
dcterms.bibliographicCitation.journaltitleBiomedical engineering = Biomedizinische Techniken
dcterms.bibliographicCitation.originalpublishernameDe Gruyteren
dcterms.bibliographicCitation.originalpublisherplaceBerlinen
dcterms.bibliographicCitation.pageend753
dcterms.bibliographicCitation.pagestart750
dcterms.bibliographicCitation.volume47
tub.accessrights.dnbdomain
tub.affiliationFak. 5 Verkehrs- und Maschinensysteme::Inst. Maschinenkonstruktion und Systemtechnikde
tub.affiliation.facultyFak. 5 Verkehrs- und Maschinensystemede
tub.affiliation.instituteInst. Maschinenkonstruktion und Systemtechnikde
tub.publisher.universityorinstitutionTechnische Universität Berlinde

Files

Original bundle
Now showing 1 - 1 of 1
Loading…
Thumbnail Image
Name:
anders_2002.pdf
Size:
1 MB
Format:
Adobe Portable Document Format

Collections