Critoph, Robert E.Metcalf, S. J.2015-11-232015-01-1320132015-01-09urn:nbn:de:kobv:83-opus4-61615https://depositonce.tu-berlin.de/handle/11303/5154http://dx.doi.org/10.14279/depositonce-4857Part of: Thermally driven heat pumps for heating and cooling. – Ed.: Annett Kühn – Berlin: Universitätsverlag der TU Berlin, 2013 ISBN 978-3-7983-2686-6 (print) ISBN 978-3-7983-2596-8 (online) urn:nbn:de:kobv:83-opus4-39458 [http://nbn-resolving.de/urn:nbn:de:kobv:83-opus4-39458]A gas-fired heat pump system intended to replace conventional condensing boilers is under development. The machine uses four sorption generators with heat recovery between all beds plus mass recovery and has a nominal heat output of 7 kW. Predicted annual average heating COP (Heat output / gas energy input based on gross calorific value) is 1.35 in a UK application with low temperature radiators. The system is described together with the simulation model, the test facilities and procedures.en620 Ingenieurwissenschaften und zugeordnete TätigkeitenActivated carbonAdsorptionAmmoniaFour bed cycleGas heat pumpDevelopment of a domestic adsorption gas-fired heat pumpBook Part